ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wildhaber, J.
Right arrow Articles by LeSouef, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wildhaber, J.
Right arrow Articles by LeSouef, P.
Eur Respir J 1996; 9: 1943-1946
Copyright © ERS Journals Ltd 1996


Original Articles

Electrostatic charge on a plastic spacer device influences the delivery of salbutamol

JH Wildhaber, SG Devadason, MJ Hayden, R James, AP Dufty, RA Fox, QA Summers, and PN LeSouef

The aim of this study was to determine whether electrostatic charge on a plastic spacer decreases the delivery of salbutamol from a pressurized metered-dose inhaler (pMDI) and, if so, to find an optimal and practical treatment to remove the charge. Ten single actuations from a salbutamol pMDI were drawn through different Volumatic spacers at a constant flow of 60 L.min-1. The efficacies of different methods of removing charge were tested, including detergent coating of the spacers. A multistage liquid impinger was used to determine the particle size distribution of the output of the pMDI through the Volumatic spacers. The electrostatic charge on the inner surface of the spacers was measured both quantitatively with an electrometer, and qualitatively by the attraction of a thin strip of cellulose membrane to the wall of the spacer. Each experiment was repeated four times. Ionic detergent coating of the spacers removed the charge for at least 24 h. This resulted in an increase of 55-70% in small particle (< 6.8 microns) delivery compared to delivery from new spacers with high charge. We have demonstrated that electrostatic charge plays a major role in the delivery of salbutamol through plastic spacers. Adequate treatment with ionic detergent removes the charge and improves drug delivery.


This article has been cited by other articles:


Home page
ChestHome page
H. M. Janssens, J. C. de Jongste, W. C. J. Hop, and H. A. W. M. Tiddens
Extra-Fine Particles Improve Lung Delivery of Inhaled Steroids in Infants: A Study in an Upper Airway Model
Chest, June 1, 2003; 123(6): 2083 - 2088.
[Abstract] [Full Text] [PDF]


Home page
Journal of Pharmacy PracticeHome page
T. P. Brock and D. M. Williams
Clinical Considerations in the Use of Inhalation Delivery Devices
Journal of Pharmacy Practice, August 1, 2001; 14(4): 277 - 295.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the European Respiratory Society.