ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thomas, D.
Right arrow Articles by Simpson, H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thomas, D.
Right arrow Articles by Simpson, H
Eur Respir J 1996; 9: 1261-1268
Copyright © ERS Journals Ltd 1996


Original Articles

Peripheral chemoresponses of infants measured by a minimally invasive method utilizing two-breath alternations in Fl,02

DA Thomas, K Poole, EK McArdle, CS Beardsmore, PC Goodenough, J Thompson, and H Simpson

The aim of this study was to develop a minimally invasive and reliable method for measuring peripheral chemoresponsiveness to oxygen in infants, and to establish baseline data from normal infants at 12 weeks of age. Two-breath alternations in fractional inspired oxygen (FI,O2), switching between 0.42 to 0.00 were given for 2 min periods via a face mask (held close to the face but without contact) to 18 healthy infants during quiet sleep. End-tidal oxygen concentrations alternated between 21 and 11%. Instantaneous minute ventilation (V'E) and its components tidal volume (VT), respiratory frequency (fR) inspiratory and expiratory times (tI and tE), inspiratory flow (VT/tT), and inspiratory duty cycle (tI/ttot) were measured by respiratory inductance plethysmography. Two-breath alternations in each of the ventilatory components were matched with the corresponding alternating end-tidal oxygen record and compared with contiguous pre- and post-test data obtained in control periods of air breathing. Alternations in all ventilatory components except fR changed significantly during FI,O2 alternations; VT 26%, tE-8%, VT/tI 18%, tI/ttot 11% and V'E 28% of baseline values. Within and between infant variances are reported for the individual components of ventilation. Differences among infants were best detected by alternations in V'E; within infant variance 76, between infant variance 171. We conclude that the test described is a safe, reliable and relatively easily applied method of measuring peripheral chemoresponsiveness, which is suitable for clinical application in infancy.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. H. Habib, K. H. Pyon, S. E. Courtney, and Z. H. Aghai
Spectral characteristics of airway opening and chest wall tidal flows in spontaneously breathing preterm infants
J Appl Physiol, May 1, 2003; 94(5): 1933 - 1940.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
B. BOUFERRACHE, S. FILTCHEV, A. LEKE, M. FREVILLE, J. GALLEGO, and C. GAULTIER
Comparison of the Hyperoxic Test and the Alternate Breath Test in Infants
Am. J. Respir. Crit. Care Med., January 15, 2002; 165(2): 206 - 210.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
U. Frey, M. Silverman, and B. Suki
Analysis of the harmonic content of the tidal flow waveforms in infants
J Appl Physiol, October 1, 2001; 91(4): 1687 - 1693.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
K. A. POOLE, H. HALLINAN, C. S. BEARDSMORE, and J. R. THOMPSON
Effect of Maternal Smoking on Ventilatory Responses to Changes in Inspired Oxygen Levels in Infants
Am. J. Respir. Crit. Care Med., September 1, 2000; 162(3): 801 - 807.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the European Respiratory Society.