ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Verschelden, P
Right arrow Articles by Malo, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Verschelden, P
Right arrow Articles by Malo, J.
Eur Respir J 1996; 9: 880-885
Copyright © ERS Journals Ltd 1996


Original Articles

Compliance with and accuracy of daily self-assessment of peak expiratory flows (PEF) in asthmatic subjects over a three month period

P Verschelden, A Cartier, J L'Archeveque, C Trudeau, and JL Malo

Serial peak expiratory flow (PEF) assessment has been proposed in the clinical evaluation of asthma. In subjects attending the asthma clinic of a tertiary care hospital, we wanted to assess: 1) compliance in performing PEF; and 2) accuracy of a PEF-diary. Twenty adult asthmatic subjects, all using inhaled steroids, were asked to assess their PEF in the morning and evening with a VMX instrument (Clement Clarke Int., Colombus, OH, USA). This instrument, which incorporates a standard mini-Wright peak flow meter, stores PEF data on a computer chip. Subjects were not informed that the values were being stored. The mean duration of PEF monitoring was 89 days (range 44-131 days). For the total of 20 subjects, it was estimated that 3,482 values should have been written down and stored on the VMX computer chip. Whilst 1,897 values (54%) were written down, only 1,533 (44%) were stored, 425 values being invented. Morning and evening values were stored on 34% of days; and values were stored at least once a day on 55% of days. The values written down corresponded precisely to stored values 90% of the time, and were within +/- 20 L 94% of the time. We conclude that: 1) compliance with daily peak expiratory flow assessments is generally poor in chronic stable asthmatic subjects assessed on two visits separated by a 3 month period; and 2) a substantial percentage of values (22%) is invented. The unsatisfactory compliance with peak expiratory flow monitoring in this group of asthmatics on inhaled steroids underlines the need for similar studies on peak expiratory flow monitoring as part of an action treatment plan, and in more severe and brittle asthmatics.


This article has been cited by other articles:


Home page
Biol Res NursHome page
C. McCarley, S. K. Hanneman, N. Padhye, and M. H. Smolensky
A pilot home study of temporal variations of symptoms in chronic obstructive lung disease.
Biol Res Nurs, July 1, 2007; 9(1): 8 - 20.
[Abstract] [PDF]


Home page
ChestHome page
V. van der Meer, H. F. van Stel, S. B. Detmar, W. Otten, P. J. Sterk, and J. K. Sont
Internet-Based Self-Management Offers an Opportunity To Achieve Better Asthma Control in Adolescents
Chest, July 1, 2007; 132(1): 112 - 119.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. S. Buist, W. M. Vollmer, S. R. Wilson, E. A. Frazier, and A. D. Hayward
A Randomized Clinical Trial of Peak Flow versus Symptom Monitoring in Older Adults with Asthma
Am. J. Respir. Crit. Care Med., November 15, 2006; 174(10): 1077 - 1087.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. A. Fonseca, A. Costa-Pereira, L. Delgado, L. N. Silva, M. Magalhaes, M. G. Castel-Branco, and M. Vaz
Pulmonary Function Electronic Monitoring Devices: A Randomized Agreement Study
Chest, September 1, 2005; 128(3): 1258 - 1265.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
H K Reddel, S D Vincent, and J Civitico
The need for standardisation of peak flow charts
Thorax, February 1, 2005; 60(2): 164 - 167.
[Abstract] [Full Text] [PDF]


Home page
Journal of Pharmacy PracticeHome page
G. Vincze and A. Parthan
The Value of Home Monitoring Kits in Diabetes, Hypertension, Asthma, and Oral Anticoagulation Therapy
Journal of Pharmacy Practice, June 1, 2004; 17(3): 182 - 196.
[Abstract] [PDF]


Home page
The Annals of PharmacotherapyHome page
J. M Tovar and J. G Gums
Monitoring Pulmonary Function in Asthma and COPD: Point-of-Care Testing
Ann. Pharmacother., January 1, 2004; 38(1): 126 - 133.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
C. A. Holcroft, E. A. Eisen, S. R. Sama, and D. H. Wegman
Measurement Characteristics of Peak Expiratory Flow
Chest, August 1, 2003; 124(2): 501 - 510.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
V. Bellia, F. Pistelli, D. Giannini, N. Scichilone, F. Catalano, M. Spatafora, R. Hopps, L. Carrozzi, S. Baldacci, F. Di Pede, et al.
Questionnaires, spirometry and PEF monitoring in epidemiological studies on elderly respiratory patients
Eur. Respir. J., May 1, 2003; 21(40_suppl): 21S - 27s.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
P. J. Sharek, M. L. Mayer, L. Loewy, T. N. Robinson, R. S. Shames, D. T. Umetsu, and D. A. Bergman
Agreement Among Measures of Asthma Status: A Prospective Study of Low-Income Children With Moderate to Severe Asthma
Pediatrics, October 1, 2002; 110(4): 797 - 804.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
H. K Reddel, B. G Toelle, G. B Marks, S. I Ware, C. R Jenkins, and A. J Woolcock
Analysis of adherence to peak flow monitoring when recording of data is electronic
BMJ, January 19, 2002; 324(7330): 146 - 147.
[Full Text] [PDF]


Home page
ThoraxHome page
A W A Kamps, R J Roorda, and P L P Brand
Peak flow diaries in childhood asthma are unreliable
Thorax, March 1, 2001; 56(3): 180 - 182.
[Abstract] [Full Text]


Home page
ChestHome page
D. M. Taylor, T. E. Auble, W. J. Calhoun, and V. N. Mosesso Jr.
Current Outpatient Management of Asthma Shows Poor Compliance With International Consensus Guidelines*
Chest, December 1, 1999; 116(6): 1638 - 1645.
[Abstract] [Full Text] [PDF]


Home page
DTBHome page
Peak flow meters and spirometers in general practice
DTB, July 1, 1997; 35(7): 52 - 55.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. O. TURNER, D. TAYLOR, R. BENNETT, and J. MARK FITZGERALD
A Randomized Trial Comparing Peak Expiratory Flow and Symptom Self-management Plans for Patients with Asthma Attending a Primary Care Clinic
Am. J. Respir. Crit. Care Med., February 1, 1997; 157(2): 540 - 546.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. CHETTA, G. GERRA, A. FORESI, A. ZAIMOVIC, M. DEL DONNO, B. CHITTOLINI, R. MALORGIO, A. CASTAGNARO, and D. OLIVIERI
Personality Profiles and Breathlessness Perception in Outpatients with Different Gradings of Asthma
Am. J. Respir. Crit. Care Med., January 1, 1997; 157(1): 116 - 122.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the European Respiratory Society.