ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smith, I.
Right arrow Articles by Shneerson, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smith, I.
Right arrow Articles by Shneerson, J.
Eur Respir J 1996; 9: 2410-2415
Copyright © ERS Journals Ltd 1996


Original Articles

A laboratory comparison of four positive pressure ventilators used in the home

IE Smith and JM Shneerson

Four brands of ventilator used for noninvasive positive pressure ventilation in the home were assessed to determine their performance on a patient simulator. We tested the tidal volume (VT) preset Companion 2801 (Puritan Bennett), minute volume preset Monnal D (Taema), and two pressure preset ventilators, the Nippy (Friday Medical) and the Bilevel Positive Airway Pressure (BiPAP) (Respironics). A patient simulator was employed to investigate the relationships between VT, peak airway pressure (PAP) and mean airway pressure (MAP), the responses to an additional leak in the circuit and patient effort of a variable duration, which was modelled using a negative pressure pump. For equivalent VTs, >300 mL, the Monnal D and Nippy generated a PAP up to 100% greater than the Companion 2801 and BiPAP. When an additional leak was introduced to the circuit, the VT of the Companion 2801 and Monnal D fell by >50%, while the Nippy and the BiPAP responded by increasing flow and maintained VT close to the level achieved with no leak. When the ventilators were triggered by a simulated patient effort of 0.25 s duration with a frequency 33% greater than that of the ventilator, the minute volume increased by 41% for the Companion 2801, by 18% for the Monnal D (no change expected), and by 17% for the Nippy (less than expected), and fell by 7% for the BiPAP due to irregular triggering. When patient effort was prolonged to 1.5 s, a similar length to the inspiratory time of the ventilators, there was no further change in the minute volume of the Companion 2801 and Monnal D, while that of the Nippy and of the BiPAP increased by 38 and 71%, respectively, compared to baseline. These results show that distinct brands of ventilator respond to changes in the patient and patient circuit in different ways, which are not always predictable from a simple description of their operating principles. This should be borne in mind when choosing a positive pressure ventilator for noninvasive ventilation.


This article has been cited by other articles:


Home page
Eur Respir JHome page
J. Gonzalez-Bermejo, V. Laplanche, F. E. Husseini, A. Duguet, J-P. Derenne, and T. Similowski
Evaluation of the user-friendliness of 11 home mechanical ventilators
Eur. Respir. J., June 1, 2006; 27(6): 1236 - 1243.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M.W. Elliott
The interface: crucial for successful noninvasive ventilation
Eur. Respir. J., January 1, 2004; 23(1): 7 - 8.
[Full Text] [PDF]


Home page
ChestHome page
M. Vitacca, L. Barbano, S. D'Anna, R. Porta, L. Bianchi, and N. Ambrosino
Comparison of Five Bilevel Pressure Ventilators in Patients With Chronic Ventilatory Failure: A Physiologic Study
Chest, December 1, 2002; 122(6): 2105 - 2114.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M.P. Highcock, E. Morrish, S. Jamieson, J.M. Shneerson, and I.E. Smith
An overnight comparison of two ventilators used in the treatment of chronic respiratory failure
Eur. Respir. J., October 1, 2002; 20(4): 942 - 945.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
Non-invasive ventilation in acute respiratory failure
Thorax, March 1, 2002; 57(3): 192 - 211.
[Full Text] [PDF]


Home page
Eur Respir JHome page
S. Mehta, F.D. McCool, and N.S. Hill
Leak compensation in positive pressure ventilators: a lung model study
Eur. Respir. J., February 1, 2001; 17(2): 259 - 267.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M.P. Highcock, J.M. Shneerson, and I.E. Smith
Functional differences in bi-level pressure preset ventilators
Eur. Respir. J., February 1, 2001; 17(2): 268 - 273.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the European Respiratory Society.