ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sampol, G
Right arrow Articles by Morell, F
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sampol, G
Right arrow Articles by Morell, F
Eur Respir J 1996; 9: 111-116
Copyright © ERS Journals Ltd 1996


Original Articles

Nasal continuous positive airway pressure with supplemental oxygen in coexistent sleep apnoea-hypopnoea syndrome and severe chronic obstructive pulmonary disease

G Sampol, MT Sagales, A Roca, MD de la Calzada, JM Bofill, and F Morell

The objective of our study was to assess the application of nasal continuous positive airway pressure (nCPAP) with supplemental oxygen for correction of upper airway obstructive episodes and hypoxaemia during sleep in stable patients with sleep apnoea-hypopnoea syndrome (SAHS) and severe chronic obstructive pulmonary disease (COPD). Ten male patients with symptomatic SAHS and severe COPD (forced expiratory volume in one second < 50% of predicted) were studied for three consecutive nights. Diagnostic polysomnography was performed the first night and repeated with increasing nCPAP levels, with and without supplemental oxygen on the second and third nights, respectively. Diagnostic polysomnography showed: mean (SD) apnoea-hypopnoea index 41 (22) events.h-1; mean arterial oxygen saturation (Sa,O2) was 86 (2)% and mean desaturation nadir was 81 (4)% during non-rapid eye movement (nREM) sleep and 80 (7)% and 73 (9)%, respectively during REM sleep. The application of nCPAP during the second night corrected apnoeas and hypopnoeas, but mean Sa,O2 remained < 90% in all patients. With the addition of oxygen at a flow of 1.5 L.min-1 at suboptimal nCPAP levels, we observed an increase in apnoea frequency, persistence of apnoeas at nCPAP levels which eliminated them when no supplemental oxygen was administered, and longer duration of apnoeas and hypopnoeas. However, when the effective nCPAP level of the second night was reached with supplemental oxygen during the third night, its efficacy in eliminating apnoeas and hypopnoeas was maintained and, furthermore, all patients presented Sa,O2 > 90%, with no greater hypercapnia cardiac arrhythmias. We conclude that nasal continuous positive airway pressure with supplemental oxygen constitutes a practical therapeutic alternative for hypoxic patients with sleep apnoea-hypopnoea syndrome and chronic obstructive pulmonary disease.


This article has been cited by other articles:


Home page
ChestHome page
R. K. Kakkar and R. B. Berry
Positive Airway Pressure Treatment for Obstructive Sleep Apnea
Chest, September 1, 2007; 132(3): 1057 - 1072.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
C.-M. Chu, V. L. Chan, D. I. Loube, P. C. Gay, K. P. Strohl, A. I. Pack, D. P. White, and N. A. Collop
Obstructive Sleep Apnea Treatment
Chest, November 1, 1999; 116(5): 1495 - 1496.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the European Respiratory Society.