ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Farre, R
Right arrow Articles by Navajas, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Farre, R
Right arrow Articles by Navajas, D
Eur Respir J 1995; 8: 1222-1227
Copyright © ERS Journals Ltd 1995


Original Articles

Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels

R Farre, M Ferrer, M Rotger, and D Navajas

Assessing respiratory impedance (Zrs) in ventilated patients over a wide frequency band, ranging from breathing rates to typical forced oscillation frequencies, during end-expiratory pauses at different positive end-expiratory pressures (PEEP) is of potential interest to assess a patient's respiratory mechanics. Zrs measurements under these conditions are not possible with the present variants of the forced oscillation technique. The aim of this work was to design a forced oscillation generator operating from spontaneous breathing frequencies whilst withstanding PEEP. To this end, we constructed a generator based on a servocontrolled loudspeaker. This allowed the loudspeaker cone to remain at its resting position regardless of the external PEEP applied. The system was optimized by using a mechanical analogue. The clinical applicability of the servocontrolled generator was assessed by measuring Zrs in mechanically-ventilated chronic obstructive pulmonary disease (COPD) patients during end-expiratory pauses at different transrespiratory pressures. The forced oscillation generator designed may be easily applicable in practice since it is small and light. The system is able to withstand transrespiratory pressures of up to 17 hPa and allows the application of forced oscillation of sufficient amplitude ( > 2 hPa peak-to-peak, 0.25-26 Hz) to obtain reliable respiratory resistance and reactance data. The servocontrolled generator permits the assessment of respiratory mechanics over a wide frequency band ranging from breathing frequencies to the most typical forced oscillation frequencies during end-expiratory pauses at PEEPs within the conventional range.


This article has been cited by other articles:


Home page
Eur Respir JHome page
Y. F. Guo, F. Herrmann, J-P. Michel, and J-P. Janssens
Normal values for respiratory resistance using forced oscillation in subjects >65 years old
Eur. Respir. J., October 1, 2005; 26(4): 602 - 608.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
E. Oostveen, D. MacLeod, H. Lorino, R. Farre, Z. Hantos, K. Desager, and F. Marchal
The forced oscillation technique in clinical practice: methodology, recommendations and future developments
Eur. Respir. J., December 1, 2003; 22(6): 1026 - 1041.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. FARRE, M. MANCINI, M. ROTGER, M. FERRER, J. ROCA, and D. NAVAJAS
Oscillatory Resistance Measured during Noninvasive Proportional Assist Ventilation
Am. J. Respir. Crit. Care Med., September 1, 2001; 164(5): 790 - 794.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. YOUNES, J. KUN, B. MASIOWSKI, K. WEBSTER, and D. ROBERTS
A Method for Noninvasive Determination of Inspiratory Resistance during Proportional Assist Ventilation
Am. J. Respir. Crit. Care Med., March 15, 2001; 163(4): 829 - 839.
[Abstract] [Full Text]