ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Van Surell, C
Right arrow Articles by Raffestin, B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Van Surell, C
Right arrow Articles by Raffestin, B
Eur Respir J 1995; 8: 795-800
Copyright © ERS Journals Ltd 1995


Original Articles

Evaluation of an ambulatory device, CID 102, in the diagnosis of obstructive sleep apnoea syndrome

C Van Surell, D Lemaigre, M Leroy, A Foucher, MP Hagenmuller, and B Raffestin

Diagnosis of obstructive sleep apnoea syndrome (OSAS) is usually performed during overnight polysomnography in the sleep laboratory. In an attempt to simplify the diagnostic strategy, we compared an ambulatory device, CID 102, with polysomnography during the same night in the laboratory in 50 consecutive patients referred for polysomnography. The CID 102 device monitors oxygen saturation, heart rate, body position and tracheal breath sounds. An acoustic pressure sensor is placed on the suprasternal notch. Signals coming from this sensor are amplified and analysed in three different channels, according to their frequency and energy. CID respiratory disturbance index is defined as the number, per hour of analysis time, of apnoeas lasting more than 10 s plus episodes of desaturation by 4% or more associated with pauses lasting from 7-10 s or snores. The polysomnographic data were recorded on paper (Reega 2000, Alvar) and analysed manually. Polysomnographic apnoea-hypopnoea index (AHIp) was defined as the number of apnoeas plus hypopnoeas per hour of sleep. The sensitivity, specificity, positive predictive value and negative predictive value of various CID respiratory disturbance index (> or = 5, > or = 10, > or = 15 and > or = 20 per hour) in diagnosing obstructive sleep apnoea syndrome were determined. When OSAS was diagnosed as AHIp > or = 15, sensitivity and specificity of a CID respiratory disturbance index > or = 5 were 73 and 62%, respectively. Positive predictive value of CID respiratory disturbance index > or = 10 for AHIp > or = 10 was 94%. CID 102 false negative patients had only hypopnoeas without any desaturation.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Eur Respir JHome page
J.M. Calleja, S. Esnaola, R. Rubio, and J. Duran
Comparison of a cardiorespiratory device versus polysomnography for diagnosis of sleep apnoea
Eur. Respir. J., December 1, 2002; 20(6): 1505 - 1510.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the European Respiratory Society.