ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gore, C.
Right arrow Articles by Owen, N
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gore, C.
Right arrow Articles by Owen, N
Eur Respir J 1995; 8: 773-782
Copyright © ERS Journals Ltd 1995


Original Articles

Spirometric standards for healthy adult lifetime nonsmokers in Australia

CJ Gore, AJ Crockett, DG Pederson, ML Booth, A Bauman, and N Owen

The aim of this study was to develop suitable spirometric prediction equations for asymptomatic Caucasian adults in the Australian population. These equations were compared with those of previous studies and constants were presented which, when associated with the prediction equations, permitted the calculation of 5% tolerance intervals for lung function. The 1,302 subjects (aged 18-78 yrs) who underwent pneumotachograph spirometry, using techniques recommended by the American Thoracic Society, were a sample from metropolitan Adelaide, South Australia. The variables recorded were sex, age, height, mass, forced expiratory volume in one second (FEV1), forced vital capacity (FVC), peak expiratory flow rate (PEFR), forced mid-expiratory flow (FEF25-75%) and FEV1/FVC ratio. Complete data were obtained for 614 females and 621 males, but the sample was reduced to 249 females and 165 males when only lifetime nonsmokers with no adverse bronchial symptoms were selected. Prediction equations of normal lung function were obtained from the reduced sample by multiple regression, with age, height and functions of both age and height as predictors. The derived equations did not differ significantly from the majority of previously reported equations and were generally superior in their ability to predict the lung function of the asymptomatic ex-smokers who were part of the original sample. Analysis of the sensitivity, specificity and predictive power of 5% tolerance limits for the presence of symptoms revealed the important roles of FEV1, FEV1/FVC and FEF25-75% in diagnostic testing. The present prediction equations are recommended for use on the Australian population and on populations with similar Caucasian characteristics.


This article has been cited by other articles:


Home page
Eur Respir JHome page
J. McCormack, S. Bell, S. Senini, K. Walmsley, K. Patel, C. Wainwright, D. Serisier, M. Harris, and S. Bowler
Daily versus weekly azithromycin in cystic fibrosis patients
Eur. Respir. J., September 1, 2007; 30(3): 487 - 495.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. Johannessen, S. Lehmann, E. R. Omenaas, G. E. Eide, P. S. Bakke, and A. Gulsvik
Post-Bronchodilator Spirometry Reference Values in Adults and Implications for Disease Management
Am. J. Respir. Crit. Care Med., June 15, 2006; 173(12): 1316 - 1325.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
S. Chinn, D. Jarvis, C. Svanes, and P. Burney
Sources of variation in forced expiratory volume in one second and forced vital capacity.
Eur. Respir. J., April 1, 2006; 27(4): 767 - 773.
[Abstract] [Full Text] [PDF]


Home page
Occup. Environ. Med.Home page
J Wu, D Griffiths, I A Kreis, and C Darling
Lung function changes in coke oven workers during 12 years of follow up
Occup. Environ. Med., August 1, 2004; 61(8): 686 - 691.
[Abstract] [Full Text] [PDF]


Home page
Occup. Environ. Med.Home page
J Wu, I A Kreis, D Griffiths, and C Darling
Cross sectional study on lung function of coke oven workers: a lung function surveillance system from 1978 to 1990
Occup. Environ. Med., December 1, 2002; 59(12): 816 - 823.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
N. E. Townsend, C. J. Gore, A. G. Hahn, M. J. McKenna, R. J. Aughey, S. A. Clark, T. Kinsman, J. A. Hawley, and C.-M. Chow
Living high-training low increases hypoxic ventilatory response of well-trained endurance athletes
J Appl Physiol, October 1, 2002; 93(4): 1498 - 1505.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
A. Langhammer, R. Johnsen, A. Gulsvik, T.L. Holmen, and L. Bjermer
Forced spirometry reference values for Norwegian adults: the Bronchial Obstruction in Nord-Trondelag study
Eur. Respir. J., November 1, 2001; 18(5): 770 - 779.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the European Respiratory Society.