ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miller, M.
Right arrow Articles by Bright, P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miller, M.
Right arrow Articles by Bright, P
Eur Respir J 1995; 8: 1637-1638
Copyright © ERS Journals Ltd 1995


Original Articles

Differences in output from corticosteroid inhalers used with a volumatic spacer

MR Miller and P Bright

Corticosteroid inhaler therapy using a spacer device is commonly used as an important part of asthma management. Increasingly, generic corticosteroid inhalers are being used with spacer devices. We have therefore tested whether these generic inhalers yield equivalence in dose when compared to the established inhalers. We measured the in vitro output, discharged into a Volumatic spacer from beclomethasone dipropionate inhalers (250 micrograms.puff-1) made by three manufacturers, Allen & Hanburys, 3M and Baker Norton. The output from 20 of each type of inhaler was sampled, in random order, by a computer driven pump system. Beclomethasone was absorbed onto a coded filter, which was analysed independently for drug content. The output per puff differed significantly between the inhalers of each manufacturer, with a 36% difference between the highest output from the Allen & Hanburys device and the lowest output device. We conclude that there are important differences in output from these inhalers when used with a spacer, and that substitution of one device with another will not necessarily give equivalent therapy to the patient.


This article has been cited by other articles:


Home page
JNMHome page
M. S. Berridge, Z. Lee, and D. L. Heald
Pulmonary Distribution and Kinetics of Inhaled [11C]Triamcinolone Acetonide
J. Nucl. Med., October 1, 2000; 41(10): 1603 - 1611.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the European Respiratory Society.