ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lodrup Carlsen, K.
Right arrow Articles by Carlsen, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lodrup Carlsen, K.
Right arrow Articles by Carlsen, K.
Eur Respir J 1994; 7: 1660-1668
Copyright © ERS Journals Ltd 1994


Original Articles

Lung function by tidal breathing in awake healthy newborn infants

KC Lodrup Carlsen, P Magnus, and KH Carlsen

The increasing availability of appliances for measuring lung function in infants may allow clinical and epidemiological applications. The aim of the present study was to establish reference values for tidal breathing lung function in awake newborn infants and to investigate potential sources of variability. Tidal flow-volume loops were measured in 803 awake, healthy infants (427 males and 376 females) and passive respiratory mechanics (single-breath occlusion technique) in 664. Mean postnatal age was 2.7 +/- 0.9 (sd) days, gestational age 39.8 +/- 1.4 weeks and birthweight 3.59 +/- 0.49 kg. Tidal expiratory volume (Vt), peak tidal expiratory flow (PEF), and mid-expiratory flow increased significantly with increasing birthweight. Flow ratios: ratio of time to PEF to total expiratory time (Tpef/Te), ratio of volume to PEF to total expiratory volume (Vpef/Ve); and ratio of tidal flow at 25% remaining expiration to PEF (TEF25/PEF), were highest in 1 day old infants (medians 0.39, 0.46 and 0.81 respectively), decreasing to a minimum in 4-5 day old infants, but were not influenced by birthweight. Tidal flows and flow ratios were higher in males versus females, even after weight adjustment. Respiratory rates correlated significantly with tidal flows (r = 0.66), inversely with Vt (r = 0.40), but not with flow ratios. Mean compliance of the respiratory system was 1.18 ml.cmH2O-1.kg birthweight (95% confidence interval (95% CI) 1.15-1.21) and mean resistance 0.051 cmH2O.ml-1.s (95% CI 0.049-0.054). These results demonstrate that lung function in awake healthy infants varies according to weight, gender and postnatal age.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
N. Beydon, S. D. Davis, E. Lombardi, J. L. Allen, H. G. M. Arets, P. Aurora, H. Bisgaard, G. M. Davis, F. M. Ducharme, H. Eigen, et al.
An Official American Thoracic Society/European Respiratory Society Statement: Pulmonary Function Testing in Preschool Children
Am. J. Respir. Crit. Care Med., June 15, 2007; 175(12): 1304 - 1345.
[Full Text] [PDF]


Home page
NEJMHome page
G. Haland, K. C. L. Carlsen, L. Sandvik, C. S. Devulapalli, M. C. Munthe-Kaas, M. Pettersen, K.-H. Carlsen, and ORAACLE
Reduced Lung Function at Birth and the Risk of Asthma at 10 Years of Age
N. Engl. J. Med., October 19, 2006; 355(16): 1682 - 1689.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
N. Katier, C. S. P. M. Uiterwaal, B. M. de Jong, J. L. L. Kimpen, and C. K. van der Ent
Feasibility and Variability of Neonatal and Infant Lung Function Measurement Using the Single Occlusion Technique
Chest, September 1, 2005; 128(3): 1822 - 1829.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
C.S. Devulapalli, G. Haaland, M. Pettersen, K.H. Carlsen, and K.C. Lodrup Carlsen
Effect of inhaled steroids on lung function in young children: a cohort study
Eur. Respir. J., June 1, 2004; 23(6): 869 - 875.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
U. Abdel-Rahman, P. Ahrens, H. G. Fieguth, R. Kitz, K. Heller, and A. Moritz
Surgical treatment of tracheomalacia by bronchoscopic monitored aortopexy in infants and children
Ann. Thorac. Surg., August 1, 2002; 74(2): 315 - 319.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G. Schmalisch, B. Foitzik, R.R. Wauer, and J. Stocks
In vitro assessment of equipment and software to assess tidal breathing parameters in infants
Eur. Respir. J., January 1, 2001; 17(1): 100 - 107.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G. Schmalisch, B. Foitzik, R.R. Wauer, and J. Stocks
Effect of apparatus dead space on breathing parameters in newborns: "flow-through" versus conventional techniques
Eur. Respir. J., January 1, 2001; 17(1): 108 - 114.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
S. Sheikh, L. J. Goldsmith, L. Howell, L. Parry, and N. Eid
Comparison of Lung Function in Infants Exposed to Maternal Smoking and in Infants With a Family History of Asthma
Chest, July 1, 1999; 116(1): 52 - 58.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1994 by the European Respiratory Society.