ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lofaso, F
Right arrow Articles by Isabey, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lofaso, F
Right arrow Articles by Isabey, D
Eur Respir J 1994; 7: 2077-2081
Copyright © ERS Journals Ltd 1994


Original Articles

Do turbines with servo-controlled speed improve continuous positive airway pressure generation?

F Lofaso, L Heyer, A Leroy, H Lorino, A Harf, and D Isabey

Nasal continuous positive airway pressure (CPAP) devices with a servo-mechanism to control pressure have recently been developed. We evaluated six such devices and three conventional systems in terms of effectiveness in maintaining constant pressure. Machines were tested with pressure levels of 5, 10 and 15 cmH2O. Dynamic behaviour was evaluated: 1) by calculating the imposed work of breathing during simulated breath generated by a sinusoidal pump; and 2) by following the fall in pressure after a transient flow of 1 l.s-1. Quasi-static behaviour was evaluated by simulating a predetermined air leak. Under dynamic conditions, work of breathing was lowest with one conventional nasal CPAP device and three servo-controlled nasal CPAP devices; whereas, the highest levels of work of breathing were recorded with two servo-controlled nasal CPAP devices. The pressure-time response to a transient flow yielded similar results, with a significant inverse correlation between pressure values observed after 300 ms and imposed work of breathing during simulated breathing (r = -0.91). Under quasi-static conditions, microprocessor servo-controlled devices exhibited the best performance. These results suggest that microprocessor servo-controlled nasal CPAP devices are not always the best systems for maintaining constant airway pressure in dynamic situations. However, they are more effective in ensuring maintenance of the desired pressure in the event of an air leak at the mask.


This article has been cited by other articles:


Home page
ChestHome page
R. Farre, J. M. Montserrat, E. Ballester, and D. Navajas
Potential Rebreathing After Continuous Positive Airway Pressure Failure During Sleep
Chest, January 1, 2002; 121(1): 196 - 200.