|
|
||||||||
Clinical Trial |
The broadening of inhaled aerosol boluses (aerosol bolus dispersion) during respiration provides a noninvasive measure of convective gas mixing in the lungs. In this study, the sensitivity and specificity of this technique for the diagnosis of early lung impairment due to cigarette smoking was evaluated. Two hundred and sixteen randomly selected subjects (126 smokers and 90 nonsmokers) were investigated with aerosol dispersion in comparison to conventional lung function tests. The cumulative cigarette consumption of the subjects was quantified by "pack-years" (PY). Smokers were classified into the following groups: 0 < PY < or = 10; 10 < PY < or = 20; 20 < PY < or = 30; and PY > 30. Forced expiratory volume in one second (FEV1), maximal expiratory flow at 25, 50 and 75% vital capacity (MEF25, MEF50 and MEF75) decreased significantly with increasing cigarette consumption. In comparison to nonsmokers, FEV1 was significantly reduced in smokers of 10 < PY < or = 30, and MEF75 was significantly reduced in smokers of PY > 20. Aerosol bolus dispersion increased with increasing PY. For all groups of smokers, even those with PY < 10, bolus dispersion was significantly increased in comparison to lifelong nonsmokers, indicating alterations in convective gas mixing in the lungs. Calculation of receiver operating characteristics for the lung function parameters under consideration showed that bolus dispersion has a higher sensitivity and specificity than conventional lung function parameters. Hence, the aerosol bolus dispersion test could be a promising epidemiological tool to study early abnormalities in intrapulmonary gas mixing due to environmental factors.
This article has been cited by other articles:
![]() |
W. Moller, K. Felten, K. Sommerer, G. Scheuch, G. Meyer, P. Meyer, K. Haussinger, and W. G. Kreyling Deposition, Retention, and Translocation of Ultrafine Particles from the Central Airways and Lung Periphery Am. J. Respir. Crit. Care Med., February 15, 2008; 177(4): 426 - 432. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Verbanck, D. Schuermans, M. Paiva, M. Meysman, and W. Vincken Small Airway Function Improvement after Smoking Cessation in Smokers without Airway Obstruction Am. J. Respir. Crit. Care Med., October 15, 2006; 174(8): 853 - 857. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. B. Shaker, N. Maltbaek, P. Brand, S. Haeussermann, and A. Dirksen Quantitative computed tomography and aerosol morphometry in COPD and {alpha}1-antitrypsin deficiency Eur. Respir. J., January 1, 2005; 25(1): 23 - 30. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Verbanck, D. Schuermans, W. Vincken, and M. Paiva Saline aerosol bolus dispersion. I. The effect of acinar airway alteration J Appl Physiol, May 1, 2001; 90(5): 1754 - 1762. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. KOHLHÄUFL, P. BRAND, C. ROCK, T. RADONS, G. SCHEUCH, T. MEYER, H. SCHULZ, K. J. PFEIFER, K. HÄUSSINGER, and J. HEYDER Noninvasive Diagnosis of Emphysema . Aerosol Morphometry and Aerosol Bolus Dispersion in Comparison to HRCT Am. J. Respir. Crit. Care Med., September 1, 1999; 160(3): 913 - 918. [Abstract] [Full Text] |
||||
![]() |
S. Verbanck, C. Darquenne, G. K. Prisk, W. Vincken, and M. Paiva A source of experimental underestimation of aerosol bolus deposition J Appl Physiol, March 1, 1999; 86(3): 1067 - 1074. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. KOHLHÄUFL, P. BRAND, G. SCHEUCH, T. S. MEYER, H. SCHULZ, K. HÄUSSINGER, and J. HEYDER Increased Fine Particle Deposition in Women with Asymptomatic Nonspecific Airway Hyperresponsiveness Am. J. Respir. Crit. Care Med., March 1, 1999; 159(3): 902 - 906. [Abstract] [Full Text] |
||||
![]() |
J. S. Brown, T. R. Gerrity, and W. D. Bennett Effect of ventilation distribution on aerosol bolus dispersion and recovery J Appl Physiol, December 1, 1998; 85(6): 2112 - 2117. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Darquenne, P. Brand, J. Heyder, and M. Paiva Aerosol dispersion in human lung: comparison between numerical simulations and experiments for bolus tests J Appl Physiol, September 1, 1997; 83(3): 966 - 974. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. VERBANCK, D. SCHUERMANS, A. VAN MUYLEM, C. MELOT, M. NOPPEN, W. VINCKEN, and M. PAIVA Conductive and Acinar Lung-zone Contributions to Ventilation Inhomogeneity in COPD Am. J. Respir. Crit. Care Med., May 1, 1997; 157(5): 1573 - 1577. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |