ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dall'Ava-Santucci, J
Right arrow Articles by Lockhart, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dall'Ava-Santucci, J
Right arrow Articles by Lockhart, A
Eur Respir J 1992; 5: 1009-1017
Copyright © ERS Journals Ltd 1992


Original Articles

Passive partitioning of respiratory volumes and time constants in ventilated patients

J Dall'Ava-Santucci, F Brunet, S Nouira, A Armaganidis, JF Dhainaut, JF Monsallier, and A Lockhart

If the thoracoabdominal partitioning of volumes in the mechanical respiratory apparatus was constant, one transducer of indirect spirometry should be sufficient to measure volume variations. To verify this hypothesis we used respiratory inductive plethysmography (RIP) in 16 paralysed patients, of whom eight had normal lungs and 8 had not, to measure: 1) the thoracoabdominal partitioning of volumes (400-1,200 ml) insufflated from either a syringe (Syr) or a ventilator (Vent); and 2) thoracic (Tho) and abdominal (Abd) time constants (T0.368) on spontaneous deflation to barometric pressure. In eleven additional subjects with normal lungs we measured only the time constants. 1) Correlation coefficients of the calibration lines were in all but one subject > 0.98. In all patients the error of volume was < +/- 10% when either one of two coils alone was used to assess volumes with no difference between the two coils; 2) Partitioning varied little with volumes (4 +/- 2%), but widely between subjects, with no group average significant difference between Syr and Vent; 3) T0.368 were identical for Tho and Abd except in one patient; 4) Partitioning and T0.368 were volume size independent. We conclude that, to measure volume variations and time constants in ventilated, paralysed patients, the use of either a thoracic or abdominal single coil RIP is justified. We also provide the normal range for time constant in 19 subjects (0.73 +/- 0.29 s).





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the European Respiratory Society.