ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gattinoni, L.
Right arrow Articles by Chiumello, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gattinoni, L.
Right arrow Articles by Chiumello, D.
Eur Respir J 2003; 22:15s-25s
Copyright ©ERS Journals Ltd 2003

Physical and biological triggers of ventilator-induced lung injury and its prevention

L. Gattinoni, E. Carlesso, P. Cadringher, F. Valenza, F. Vagginelli and D. Chiumello

Institute of Anaesthesia and Intensive Care, University of Milan, Policlinico Hospital, IRCCS, Milan, Italy

CORRESPONDENCE: L. Gattinoni, Istituto di Anestesia e Rianimazione, Ospedale Maggiore Policlinico-IRCCS, Via Francesco Sforza, 35, 20122, Milano, Italy. Fax: 39 0255033230. E-mail: gattinon@policlinico.mi.it

Keywords: acute respiratory distress syndrome, elastance, respiratory mechanics, stress/strain, ventilator-induced lung injury

Received: February 25, 2003
Accepted July 14, 2003

Ventilator-induced lung injury is a side-effect of mechanical ventilation. Its prevention or attenuation implies knowledge of the sequence of events that lead from mechanical stress to lung inflammation and stress at rupture.

A literature review was undertaken which focused on the link between the mechanical forces in the diseased lung and the resulting inflammation/rupture.

The distending force of the lung is the transpulmonary pressure. This applied force, in a homogeneous lung, is shared equally by each fibre of the lung's fibrous skeleton. In a nonhomogeneous lung, the collapsed or consolidated regions do not strain, whereas the neighbouring fibres experience excessive strain. Indeed, if the global applied force is excessive, or the fibres near the diseased regions experience excessive stress/strain, biological activation and/or mechanical rupture are observed. Excessive strain activates macrophages and epithelial cells to produce interleukin-8. This cytokine recruits neutrophils, with consequent full-blown inflammation.

In order to prevent initiation of ventilator-induced lung injury, transpulmonary pressure must be kept within the physiological range. The prone position may attenuate ventilator-induced lung injury by increasing the homogeneity of transpulmonary pressure distribution. Positive end-expiratory pressure may prevent ventilator-induced lung injury by keeping open the lung, thus reducing the regional stress/strain maldistribution. If the transpulmonary pressure rather than the tidal volume per kilogram of body weight is taken into account, the contradictory results of the randomised trials dealing with different strategies of mechanical ventilation may be better understood.




This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
J. Mancebo, R. Fernandez, L. Blanch, G. Rialp, F. Gordo, M. Ferrer, F. Rodriguez, P. Garro, P. Ricart, I. Vallverdu, et al.
A Multicenter Trial of Prolonged Prone Ventilation in Severe Acute Respiratory Distress Syndrome
Am. J. Respir. Crit. Care Med., June 1, 2006; 173(11): 1233 - 1239.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the European Respiratory Society.