ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schoni, M.
Right arrow Articles by Kraemer, R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schoni, M.
Right arrow Articles by Kraemer, R
Eur Respir J 1989; 2: 887-892
Copyright © ERS Journals Ltd 1989


Original Articles

Osmolality changes in nebulizer solutions

MH Schoni and R Kraemer

Paradoxical effects (bronchoconstriction instead of bronchodilatation) have been reported after inhalation of beta2-mimetics in asthmatic children, and it has been suggested that this was due to osmolality and pH changes of the nebulizer solution. We tested commercially available nebulizer solutions and found osmolality changes after 5, 10 and 15 min of nebulization. Osmolality was measured in the nebulizer chamber and the airsteam of two types of jet nebulizers. When normal saline was nebulized chamber, from 282 +/- 7 mmol.kg-1 to 432 +/- 18 mmol.kg-1 resulted. Salbutamol ready made solution, and terbutaline respules were isotonic, whereas fenoterol, disodium cromogylcate (DSCG), beclomethasone dipropionate (BDP) and salbutamol (respirator solution 0.5%) were hypotonic (60-100 mmol.kg-1). When a mixture of sodium chloride (NaCl) and the drug solution (salbutamol, terbutaline, fenoterol) was nebulized for 10-15 min, the osmolality in the nebulizer cup increased to 420-500 mmol.kg-1. However, mixtures of the same beta 2-agonists with DSCG or with BDP remained hypo-osmolar. The same osmolality changes were present in the airstream. This study shows that after 10-15 min of nebulization osmotic changes occur in the nebulizer cup and airstream and that these changes differ according to the drug mixtures and the amount of the solution in the nebulizer chamber.


This article has been cited by other articles:


Home page
Am J Health Syst PharmHome page
T.-Y. Lee, C.-M. Chen, C.-N. Lee, Y.-C. Chiang, and H.-Y. Chen
Compatibility and osmolality of inhaled N-acetylcysteine nebulizing solution with fenoterol and ipratropium
Am. J. Health Syst. Pharm., April 15, 2005; 62(8): 828 - 833.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1989 by the European Respiratory Society.