ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bregeon, F
Right arrow Articles by Auffray, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bregeon, F
Right arrow Articles by Auffray, J.
Eur Respir J 2000; 16: 969-975
Copyright © ERS Journals Ltd 2000


Original Articles

Diagnostic accuracy of protected catheter sampling in ventilator-associated bacterial pneumonia

F Bregeon, L Papazian, P Thomas, V Carret, L Garbe, P Saux, M Drancourt, and JP Auffray

The aim of this study was to assess the accuracy of protected telescoping catheter performed using: 1) protected distal aspiration, or 2) protected mini-bronchoalveolar lavage for the diagnosis of ventilator-associated bacterial pneumonia. Twenty-seven patients who died after receiving mechanical ventilation for at least 72 h were included in a comparative prospective post-mortem study. The two microbiological sampling procedures were performed immediately after death. Surgical pneumonectomies and biopsies were performed within 30 min of death at the bedside for histological examination. The results of the two techniques were compared with histological post-mortem lung examination or biopsies. Histological examination of the parenchyma showed signs of pneumonia in 14 cases. Lung tissue culture was positive in nine of these 14 cases. When ventilator-associated bacterial pneumonia was defined by the association of histological signs and positive lung tissue culture the sensitivity was 78% for both sampling techniques, specificity was 86% for mini-bronchoalveolar lavage and 100% for protected distal aspiration (at a threshold of 1 x 10(3) cfu x mL(-1)). Both techniques protected the distal aspiration and mini-bronchoalveolar lavage, and provided good specificity with an acceptable sensitivity for the diagnosis of ventilator-associated bacterial pneumonia.


This article has been cited by other articles:


Home page
ChestHome page
E. Kipnis, K. Hansen, T. Sawa, K. Moriyama, A. Zurawel, A. Ishizaka, and J. Wiener-Kronish
Proteomic Analysis of Undiluted Lung Epithelial Lining Fluid
Chest, August 1, 2008; 134(2): 338 - 345.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
M. Klompas and R. Platt
Ventilator-Associated Pneumonia The Wrong Quality Measure for Benchmarking
Ann Intern Med, December 4, 2007; 147(11): 803 - 805.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
M. Klompas
Does This Patient Have Ventilator-Associated Pneumonia?
JAMA, April 11, 2007; 297(14): 1583 - 1593.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
G. Hugues, L. Olivier, G. Benoit, B. Allaouchiche, E. Boselli, S. Gibot, B. Levy, and M.-C. Bene
Soluble TREM-1 and the Diagnosis of Pneumonia
N. Engl. J. Med., April 29, 2004; 350(18): 1904 - 1905.
[Full Text] [PDF]


Home page
Eur Respir JHome page
J-Y. Fagon and J. Chastre
Diagnosis and treatment of nosocomial pneumonia in ALI/ARDS patients
Eur. Respir. J., August 1, 2003; 22(42_suppl): 77s - 83s.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J. Chastre and J.-Y. Fagon
Ventilator-associated Pneumonia
Am. J. Respir. Crit. Care Med., April 1, 2002; 165(7): 867 - 903.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the European Respiratory Society.