ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Newman, S.
Right arrow Articles by Hermann, R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Newman, S.
Right arrow Articles by Hermann, R
Eur Respir J 2000; 16: 178-183
Copyright © ERS Journals Ltd 2000


Clinical Trial

Scintigraphic comparison of budesonide deposition from two dry powder inhalers

SP Newman, GR Pitcairn, PH Hirst, RE Bacon, E O'Keefe, M Reiners, and R Hermann

Chlorofluorocarbons (CFCs), used in metered dose inhalers (MDIs), have been identified as being deleterious to the environment leading to a ban on their production. Dry powder inhalers (DPIs) are a widely used alternative to MDIs. One disadvantage of DPIs is that in vivo lung deposition can be influenced by the patient's inspiratory flow rate. The ASTA Medica multi-dose dry powder inhaler (AM-MDPI) has been designed to offer low resistance on inhalation, so that asthmatic patients can achieve inhaled flow rates of approximately 90 L x min(-1). The aim of the study was to evaluate the in vivo deposition of budesonide from the AM-MDPI at different flow rates and to compare this with delivery from a Turbuhaler DPI at a high flow rate. The study was a scintigraphic, randomized, crossover study in which 13 healthy volunteers inhaled a single 200 microg dose of radiolabelled budesonide on four separate occasions with a minimum 44-h washout period between dosings. At the lowest flow rate of 54 L x min(-1), comparable to that for the Turbuhaler (58 L x min(-1)), a similar percentage of the metered dose was delivered to the lung (AM-MDPI median 19.9%; Turbuhaler median 21.4%). At high flow rate (peak inspiratory flow rate 99 L x min(-1)) the AM-MDPI delivered significantly more drug to the lung (median 32.1% of metered dose) than at 65 L x min(-1) or 54 L x min(-1) (median 25.0% and 19.9% of metered dose, respectively), thus demonstrating flow rate dependence. The pattern of regional lung deposition from the AM-MDPI was similar for all three inhalation manoeuvres. It was concluded that the ASTA Medica multi-dose dry powder inhaler achieves at least as much deposition of budesonide in the lungs as a Turbuhaler when used at similar inspiratory flow rates.


This article has been cited by other articles:


Home page
J Clin PharmacolHome page
R. Hermann, W. Siegmund, T. Giessmann, K. Westphal, A. Weinbrenner, B. Hauns, F. Reutter, G. Lahu, K. Zech, and T. D. Bethke
The Oral, Once-Daily Phosphodiesterase 4 Inhibitor Roflumilast Lacks Relevant Pharmacokinetic Interactions With Inhaled Budesonide
J. Clin. Pharmacol., August 1, 2007; 47(8): 1005 - 1013.
[Abstract] [Full Text] [PDF]


Home page
ERRHome page
P. Barnes, J. C. Virchow, J. Sanchis, T. Welte, and S. Pedersen
Asthma management: important issues
Eur. Respir. Rev., December 1, 2005; 14(97): 147 - 151.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the European Respiratory Society.