ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lofaso, F
Right arrow Articles by Harf, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lofaso, F
Right arrow Articles by Harf, A
Eur Respir J 2000; 15: 338-341
Copyright © ERS Journals Ltd 2000


Original Articles

Inaccuracy of tidal volume delivered by home mechanical ventilators

F Lofaso, R Fodil, H Lorino, K Leroux, A Quintel, A Leroy, and A Harf

Ideally, the inspired (tidal) volume (V(T)) provided by a volume-controlled ventilation device should not change when the pressure imposed on the ventilator varies. A bench study evaluation of V(T) versus pressure was performed on 10 commercially available devices. The difference between the desired V(T) and the observed V(T) reached 100 mL for some devices when inspiratory resistance was at its lowest, rising to 150 mL when inspiratory resistance was increased to obtain peak airway pressure of 60 cmH2O. The present data indicate that some home ventilators are inaccurate in delivering the preset tidal volume when the pressure imposed on the ventilator is increased to simulate high airway resistance.


This article has been cited by other articles:


Home page
Eur Respir JHome page
B. Fauroux, K. Leroux, G. Desmarais, D. Isabey, A. Clement, F. Lofaso, and B. Louis
Performance of ventilators for noninvasive positive-pressure ventilation in children
Eur. Respir. J., June 1, 2008; 31(6): 1300 - 1307.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J. Gonzalez-Bermejo, V. Laplanche, F. E. Husseini, A. Duguet, J-P. Derenne, and T. Similowski
Evaluation of the user-friendliness of 11 home mechanical ventilators
Eur. Respir. J., June 1, 2006; 27(6): 1236 - 1243.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
R Farre, D Navajas, E Prats, S Marti, R Guell, J M Montserrat, C Tebe, and J Escarrabill
Performance of mechanical ventilators at the patient's home: a multicentre quality control study
Thorax, May 1, 2006; 61(5): 400 - 404.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
R. Farre, S. J. Lloyd-Owen, N. Ambrosino, G. Donaldson, J. Escarrabill, B. Fauroux, D. Robert, B. Schoenhofer, A. Simonds, and J. A. Wedzicha
Quality control of equipment in home mechanical ventilation: a European survey
Eur. Respir. J., July 1, 2005; 26(1): 86 - 94.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
H. Prigent, C. Samuel, B. Louis, M.-F. Abinun, F. Zerah-Lancner, M. Lejaille, J.-C. Raphael, and F. Lofaso
Comparative Effects of Two Ventilatory Modes on Speech in Tracheostomized Patients with Neuromuscular Disease
Am. J. Respir. Crit. Care Med., January 15, 2003; 167(2): 114 - 119.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
B. Schonhofer and S. Sortor-Leger
Equipment needs for noninvasive mechanical ventilation
Eur. Respir. J., October 1, 2002; 20(4): 1029 - 1036.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M.W. Elliott, M. Confalonieri, and S. Nava
Where to perform noninvasive ventilation?
Eur. Respir. J., June 1, 2002; 19(6): 1159 - 1166.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
S. MEHTA and N. S. HILL
Noninvasive Ventilation
Am. J. Respir. Crit. Care Med., February 1, 2001; 163(2): 540 - 577.