ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Navajas, D
Right arrow Articles by Peslin, R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Navajas, D
Right arrow Articles by Peslin, R
Eur Respir J 2000; 15: 185-191
Copyright © ERS Journals Ltd 2000


Original Articles

A simplified method for monitoring respiratory impedance during continuous positive airway pressure

D Navajas, C Duvivier, R Farre, and R Peslin

The forced oscillation technique is useful in detecting changes in upper airway obstruction in patients with sleep apnoea undergoing continuous positive airway pressure (CPAP) ventilation. The aim of this study was to implement and evaluate a method for estimating respiratory impedance (Zrs) from the pressure and flow recorded at the inlet of the CPAP tubing. The method is based on correcting impedance measured at the inlet of the CPAP tubing (Zi) for the effect of the tubing and the exhalation port. The method was evaluated in mechanical analogues and in a healthy subject. Sinusoidal oscillation of 5, 10 and 20 Hz were superimposed on CPAP (5-15 cmH2O). At 5 Hz, the changes in airflow obstruction were substantially underestimated by Zi. Furthermore, Zi exhibited a negative dependence on Zrs at 20 Hz. The assessment of Zrs was greatly improved after correcting Zi for the effects of the CPAP tubing and the exhalation port. Zrs was well estimated at low frequencies, reaching very high values during total occlusion (>60 cmH2O x s x L(-1) at 5-10 Hz). These results indicate that changes in airflow obstruction can be detected using the forced oscillation technique from pressure and flow recorded on the continuous positive airway pressure device. This facilitates the clinical application of the forced oscillation technique for monitoring upper airway patency during sleep.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
M. YOUNES, J. KUN, B. MASIOWSKI, K. WEBSTER, and D. ROBERTS
A Method for Noninvasive Determination of Inspiratory Resistance during Proportional Assist Ventilation
Am. J. Respir. Crit. Care Med., March 15, 2001; 163(4): 829 - 839.
[Abstract] [Full Text]


Home page
Eur Respir JHome page
R. Farre, J. Rigau, J.M. Montserrat, E. Ballester, and D. Navajas
Evaluation of a simplified oscillation technique for assessing airway obstruction in sleep apnoea
Eur. Respir. J., March 1, 2001; 17(3): 456 - 461.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the European Respiratory Society.