Eur Respir J 1999; 13: 767-774
Copyright © ERS Journals Ltd 1999
Effects of endothelin-1 on airway and parenchymal mechanics in guinea-pigs
A Adamicza,
F Petak,
T Asztalos,
and
Z Hantos
The contributions of the airways and the parenchyma to the overall lung mechanical response to endothelin-1 (ET-1) have not been systematically studied. In this investigation, the ET-1 induced changes on lung mechanics in guinea-pigs were separated into airway and parenchymal components. Pulmonary impedance (ZL) data were collected between 0.5 and 21 Hz in six anaesthetized, paralysed, open-chest animals by introducing small-amplitude pseudorandom oscillations into the trachea through a wave tube. ZL was calculated before and following intravenous boluses of ET-1, with doses doubled from 0.125-2 microg x kg of body weight(-1). A model containing an airway resistance (Raw) and inertance (Iaw) and tissue damping (G) and elastance (H) was fitted to the ZL spectra in each condition. Parenchymal hysteresis (eta) was calculated as G/H. After each dose, ET-1 induced significant increases in Raw (at peak response mean+/-SEM: 424+/-129%), G (400+/-80%), H (95+/-22%) and eta (156+/-33%), whereas Iaw decreased following the two highest doses (-291+/-77%). These data suggest that the parenchymal constriction was accompanied by inhomogeneous constriction of the peripheral airways.
This article has been cited by other articles:

|
 |

|
 |
 
L. E. Kandalaft, A. Facciabene, R. J. Buckanovich, and G. Coukos
Endothelin B Receptor, a New Target in Cancer Immune Therapy
Clin. Cancer Res.,
July 15, 2009;
15(14):
4521 - 4528.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Ito, E. P. Ingenito, S. P. Arold, H. Parameswaran, N. T. Tgavalekos, K. R. Lutchen, and B. Suki
Tissue heterogeneity in the mouse lung: effects of elastase treatment
J Appl Physiol,
July 1, 2004;
97(1):
204 - 212.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
N. Schutz, F. Petak, C. Barazzone-Argiroffo, F. Fontao, and W. Habre
Effects of volatile anaesthetic agents on enhanced airway tone in sensitized guinea pigs
Br. J. Anaesth.,
February 1, 2004;
92(2):
254 - 260.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. V. Romero, W. A. Zin, and J. Lopez-Aguilar
Frequency characteristics of lung tissue strip during passive stretch and induced pneumoconstriction
J Appl Physiol,
August 1, 2001;
91(2):
882 - 890.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
F. Petak, W. Habre, Y. R. Donati, Z. Hantos, and C. Barazzone-Argiroffo
Hyperoxia-induced changes in mouse lung mechanics: forced oscillations vs. barometric plethysmography
J Appl Physiol,
June 1, 2001;
90(6):
2221 - 2230.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Adamicza, F. Petak, T. Asztalos, L. Tiszlavicz, M. Boros, and Z. Hantos
Endothelin-1-induced airway and parenchymal mechanical responses in guinea-pigs: the roles of ETA and ETB receptors
Eur. Respir. J.,
May 1, 2001;
17(5):
975 - 981.
[Abstract]
[Full Text]
[PDF]
|
 |
|
Copyright © 1999 by the European Respiratory Society.
|