ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brown, K
Right arrow Articles by Stocks, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brown, K
Right arrow Articles by Stocks, J
Eur Respir J 1998; 12: 935-943
Copyright © ERS Journals Ltd 1998


Clinical Trial

Validation of respiratory inductive plethysmography using the Qualitative Diagnostic Calibration method in anaesthetized infants

K Brown, C Aun, E Jackson, A Mackersie, D Hatch, and J Stocks

The aim of this study was to compare tidal volume (VT) derived from the Qualitative Diagnostic Calibration (QDC) method (VT,QDC) with measurements from pneumotachography (VT,PN,T) in anaesthetized infants. Measurements were made during spontaneous (SV) and intermittent positive pressure (IPPV) ventilation, sighs and airway occlusions. The VT,DIF was the difference between VT,QDC and VT,PNT (%VT). The contribution of the ribcage (rc) to VT,QDC (%rc) and the thoracoabdominal phase lag were also derived. Twenty-eight infants, mean (SD) age 14.0 (6.2) months were studied. VT,QDC represented VT,PNT most closely when > or = 20 breaths were analysed. There was close agreement during SV immediately after the calibration period (95% limits of agreement (LA; QDC - PNT) -23, 3.0%). The 95% LA increased to -9.6, 10.2% after 10 min. Accuracy diminished during IPPV (95% LA -38, 31%), and sighs. During airway occlusions, when VT,PNT was zero, the 95% LA were -63, 4.1 mL x kg(-1). Mean phase lag was 36 and 2%, respectively, during SV and IPPV (p<0.05). The %rc appeared to be overestimated, being in excess of 50% in infants under 12 months. The Qualitative Diagnostic Calibration method used to estimate tidal volume in anaesthetized infants was limited by the need to analyse > or = 20 breaths and by a loss of within-subject accuracy if measurement conditions or pattern of breathing changed.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
A. De Groote, M. Paiva, and Y. Verbandt
Mathematical assessment of qualitative diagnostic calibration for respiratory inductive plethysmography
J Appl Physiol, March 1, 2001; 90(3): 1025 - 1030.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
G. Schmalisch, B. Foitzik, R.R. Wauer, and J. Stocks
Effect of apparatus dead space on breathing parameters in newborns: "flow-through" versus conventional techniques
Eur. Respir. J., January 1, 2001; 17(1): 108 - 114.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the European Respiratory Society.