ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kampelmacher, M.
Right arrow Articles by Lammers, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kampelmacher, M.
Right arrow Articles by Lammers, J.
Eur Respir J 1998; 12: 204-207
Copyright © ERS Journals Ltd 1998


Original Articles

Accuracy of oxygen delivery by liquid oxygen canisters

MJ Kampelmacher, PB Cornelisse, GP Alsbach, RG van Kesteren, CF Melissant, JM Douze, and JW Lammers

The oxygen flow rate delivered by liquid oxygen canisters may be less than intended, owing to inaccuracies of the set flow rates and/or as a result of the outflow resistance caused by the humidifier, oxygen tubing, delivery or conserving device. The aim of this study was to investigate the accuracy of oxygen delivery by liquid oxygen canisters at different flow rates and levels of outflow resistance. Four stationary and 18 portable liquid oxygen canisters from three manufacturers were tested. All flows were measured using a Timemeter RT 200 Calibration Analyser. An adjustable obstruction was used to calculate the effect of the outflow resistance on the delivered flow rate. The measured and set flow rates of both stationary and portable canisters were strongly correlated. Expressed as a percentage of the set flow rate, the measured flow rate of the canisters varied from 36-128%, with the lowest values at flow rates <1 L x min(-1). Sixty-two (26%) of the measured flow rates differed > or =10% from the set flow rate. A difference of 0.5-1.0 L x min(-1) occurred in 16 (7%) of the measurements, but only at set flow rates >2 L x min(-1). Irrespective of the set flow rate, the measured flow rate was hardly affected by the outflow resistance. We conclude that the accuracy of oxygen delivery by liquid oxygen canisters depends on the inaccuracy of the set flow rates rather than on the outflow resistance, even at high flow rates. Although the differences between the measured and set flow rates were mostly small, they may have clinical significance, particularly in patients with chronic obstructive pulmonary disease. To prevent inaccuracy, monthly checks of the canisters by the oxygen provider at the patient's home are more important than yearly maintenance.


This article has been cited by other articles:


Home page
Chronic Respiratory DiseaseHome page
D L Cullen and J A Koss
Oxygen tubing lengths and output flows: implications for patient care
Chronic Respiratory Disease, October 1, 2005; 2(4): 193 - 197.