ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lofaso, F
Right arrow Articles by Brochard, L
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lofaso, F
Right arrow Articles by Brochard, L
Eur Respir J 1998; 11: 1382-1388
Copyright © ERS Journals Ltd 1998


Clinical Trial

Expiratory valves used for home devices: experimental and clinical comparison

F Lofaso, P Aslanian, JC Richard, D Isabey, T Hang, E Corriger, A Harf, and L Brochard

A bench study followed by a clinical trial were performed to evaluate the mechanical characteristics of five (commercially available) expiratory valves used for home ventilators, as well as the potential clinical impact of differences between these valves. In the in vitro study, expiratory valve resistance was evaluated under unvarying conditions, whereas dynamic behaviour was evaluated by calculating the imposed expiratory work of breathing during a simulated breath generated by a lung model. Differences in resistance and imposed expiratory work of up to twofold and 150%, respectively, were found across valves. We then conducted a randomized crossover clinical study to compare the effects of the least resistive (Bennett) and most resistive expiratory valves (Peters) in 10 intubated patients receiving pressure support ventilation. There were no significant differences regarding blood gases or respiratory parameters except for the oesophageal pressure-time product (PTPoes), which was significantly increased by the Peters valve (236+/-113 cmH2O x s x min(-1) versus 194+/-90 cmH2O x s x min(-1)). An analysis of individual responses found that the Peters valve induced substantial increases in intrinsic positive end-expiratory pressure (PEEP), PTPoes, and expiratory activity in those patients with the greatest ventilatory demand. In conclusion, differences between home expiratory valve resistances may have a clinically relevant impact on the respiratory effort of patients with a high ventilatory demand.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
T. Sharshar, G. Desmarais, B. Louis, G. Macadou, R. Porcher, A. Harf, J.-C. Raphael, D. Isabey, and F. Lofaso
Transdiaphragmatic Pressure Control of Airway Pressure Support in Healthy Subjects
Am. J. Respir. Crit. Care Med., October 1, 2003; 168(7): 760 - 769.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
B. Schonhofer and S. Sortor-Leger
Equipment needs for noninvasive mechanical ventilation
Eur. Respir. J., October 1, 2002; 20(4): 1029 - 1036.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
F. Lofaso, M. P. d'Ortho, R. Fodil, C. Delclaux, A. Harf, and A. M. Lorino
Abdominal Muscle Activity in Sleep Apnea During Continuous Positive Airway Pressure Titration
Chest, August 1, 2001; 120(2): 390 - 396.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. Vitacca, S. Nava, M. Confalonieri, L. Bianchi, R. Porta, E. Clini, and N. Ambrosino
The Appropriate Setting of Noninvasive Pressure Support Ventilation in Stable COPD Patients
Chest, November 1, 2000; 118(5): 1286 - 1293.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS