ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meurice, J.
Right arrow Articles by Series, F
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meurice, J.
Right arrow Articles by Series, F
Eur Respir J 1998; 11: 1121-1127
Copyright © ERS Journals Ltd 1998


Clinical Trial

Influence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea/hypopnoea syndrome

JC Meurice, J Paquereau, A Denjean, F Patte, and F Series

We evaluated the efficiency of two different treatment procedures with continuous positive airway pressure (CPAP) on sleep, nocturnal breathing characteristics and daytime vigilance in 18 newly diagnosed patients with untreated sleep apnoea/hypopnoea syndrome (SAHS) randomly allocated to two different groups. In group I, the positive pressure (PP) level was set to suppress flow limitation (PFL), while in group II the PP was set at a level that eliminated only apnoea/hypopnoea and snoring (PAHS). At the end of a 3 week period of home CPAP therapy, a follow-up sleep study, vigilance and cognitive tests were made. Overall, PFL was significantly higher than PAHS values (PFL: 10.42.6 cmH2O; PAHS: 8.9+/-2.6 cmH2O; p<0.01, mean+/-SD). We found no difference in sleep quality, nocturnal saturation and apnoea/hypopnoea index, or in daytime vigilance tests between the two groups at the end of the treatment period. However, there was a significantly greater scattering in the changes of sleep latency in group II than in group I. This was associated with a significant difference in the daily duration of nasal CPAP use between the two groups (group I: 7.29+/-0.95 h x day(-1); group II: 6.01+/-0.94 h x day(-1); p=0.01) and with a positive correlation between final maintenance of wakefulness test values and the duration of CPAP use (p<0.05; r=0.55). These results tend to show that correcting flow limitation is associated with a higher observance and a more important efficiency in normalizing daytime vigilance than with conventional nasal continuous positive airway pressure.


This article has been cited by other articles:


Home page
Proc Am Thorac SocHome page
M. H. Sanders, J. M. Montserrat, R. Farre, and R. J. Givelber
Positive Pressure Therapy: A Perspective on Evidence-based Outcomes and Methods of Application
Proceedings of the ATS, February 15, 2008; 5(2): 161 - 172.
[Abstract] [Full Text] [PDF]


Home page
ERRHome page
D. Pevernagie, J. F. Masa, J. C. Meurice, R. Farre, O. Marrone, and D. Rodenstein
Treatment of obstructive sleep-disordered breathing with positive airway pressure systems
Eur. Respir. Rev., December 1, 2007; 16(106): 125 - 131.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
R. K. Kakkar and R. B. Berry
Positive Airway Pressure Treatment for Obstructive Sleep Apnea
Chest, September 1, 2007; 132(3): 1057 - 1072.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
F. Lofaso, G. Desmarais, K. Leroux, V. Zalc, R. Fodil, D. Isabey, and B. Louis
Bench evaluation of flow limitation detection by automated continuous positive airway pressure devices.
Chest, August 1, 2006; 130(2): 343 - 349.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
A. Noseda, C. Kempenaers, M. Kerkhofs, S. Braun, P. Linkowski, and E. Jann
Constant vs Auto-Continuous Positive Airway Pressure in Patients With Sleep Apnea Hypopnea Syndrome and a High Variability in Pressure Requirement
Chest, July 1, 2004; 126(1): 31 - 37.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
S. T. Kuna
Can Continuous Positive Airway Pressure Be Self-Titrated?
Am. J. Respir. Crit. Care Med., March 1, 2003; 167(5): 674 - 675.
[Full Text] [PDF]


Home page
J. Physiol.Home page
E Verin, T Similowski, and F Series
Effects of continuous positive airway pressure on upper airway inspiratory dynamics in awake patients with sleep-disordered breathing
J. Physiol., January 1, 2003; 546(1): 279 - 287.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
W. J. RANDERATH, O. SCHRAEDER, W. GALETKE, F. FELDMEYER, and K.-H. RUHLE
Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance
Am. J. Respir. Crit. Care Med., March 1, 2001; 163(3): 652 - 657.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M.-P. d'Ortho, V. Grillier-Lanoir, P. Levy, F. Goldenberg, E. Corriger, A. Harf, and F. Lofaso
Constant vs Automatic Continuous Positive Airway Pressure Therapy : Home Evaluation
Chest, October 1, 2000; 118(4): 1010 - 1017.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J. R. BADIA, R. JOHN KIMOFF, E. BALLESTER, L. HERNÁNDEZ, M. ROTGER, D. NAVAJAS, and J. M. MONTSERRAT
Clinical Application of the Forced Oscillation Technique for CPAP Titration in the Sleep Apnea/Hypopnea Syndrome
Am. J. Respir. Crit. Care Med., November 1, 1999; 160(5): 1550 - 1554.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the European Respiratory Society.