Eur Respir J 1998; 11: 467-472
Copyright © ERS Journals Ltd 1998
Exhaled single-breath nitric oxide measurements are reproducible, repeatable and reflect levels of nitric oxide found in the lower airways
E Gabbay,
AJ Fisher,
T Small,
AJ Leonard,
and
PA Corris
Measurement of exhaled nitric oxide (NO) may allow noninvasive assessment of inflammatory disease in the lung. We determined immediate and day-to-day reproducibility of single-breath NO measurements at different points on the exhaled test, and whether levels recorded reflect levels of NO in the lower airways. Using a rapid chemiluminescence analyser, 55 healthy control subjects performed three sequential tests on each of two days. NO levels were compared at the level corresponding with: 1) the time the mouth pressure fell below 4 cmH2O (MP); 2) the plateau of end-exhaled CO2 (CO2); and 3) the NO plateau (NOp). NO levels were measured directly from the lower airways of 15 lung transplant recipients and compared with NO levels from a single-breath test performed in the same cohort. For measurements performed at MP, CO2 and NOp, the mean +/- SD differences between the two closest levels performed on the same day were 0.11+/-0.18, 0.095+/-0.16 and 0.094+/-0.13 parts per billion (ppb), respectively, and between days were 0.18+/-0.76, 0.19+/-0.78 and 0.17+/-0.8 ppb, respectively. End-expiratory levels recorded at the mouth from a single-breath test and in the lower airways were highly correlated (mouth versus trachea r2=0.95, p<0.0001, mouth versus bronchus r2=0.92, p<0.0001). Single-breath exhaled nitric oxide levels are a simple, reproducible and valid measure of nitric oxide production from the lower respiratory tract.
This article has been cited by other articles:

|
 |

|
 |
 
Y. Kerckx and A. Van Muylem
Axial distribution heterogeneity of nitric oxide airway production in healthy adults
J Appl Physiol,
June 1, 2009;
106(6):
1832 - 1839.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D R Taylor, M W Pijnenburg, A D Smith, and J C D Jongste
Exhaled nitric oxide measurements: clinical application and interpretation
Thorax,
September 1, 2006;
61(9):
817 - 827.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
I. Hubloue, D. Biarent, S. A. Kafi, G. Bejjani, F. Kerbaul, R. Naeije, and M. Leeman
Endogenous endothelins and nitric oxide in hypoxic pulmonary vasoconstriction
Eur. Respir. J.,
January 1, 2003;
21(1):
19 - 24.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. De SOYZA, A. J. FISHER, T. SMALL, and P. A. CORRIS
Inhaled Corticosteroids and the Treatment of Lymphocytic Bronchiolitis Following Lung Transplantation
Am. J. Respir. Crit. Care Med.,
October 1, 2001;
164(7):
1209 - 1212.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
E. GABBAY, E. HAYDN WALTERS, B. ORSIDA, H. WHITFORD, C. WARD, T. C. KOTSIMBOS, G. I. SNELL, and T. J. WILLIAMS
Post-lung Transplant Bronchiolitis Obliterans Syndrome (BOS) Is Characterized by Increased Exhaled Nitric Oxide Levels and Epithelial Inducible Nitric Oxide Synthase
Am. J. Respir. Crit. Care Med.,
December 1, 2000;
162(6):
2182 - 2187.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
E. Clini, L. Bianchi, M. Vitacca, R. Porta, K. Foglio, and N. Ambrosino
Exhaled Nitric Oxide and Exercise in Stable COPD Patients
Chest,
March 1, 2000;
117(3):
702 - 707.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
E. GABBAY, E. HAYDN WALTERS, B. ORSIDA, H. WHITFORD, C. WARD, T. C. KOTSIMBOS, G. I. SNELL, and T. J. WILLIAMS
In Stable Lung Transplant Recipients, Exhaled Nitric Oxide Levels Positively Correlate with Airway Neutrophilia and Bronchial Epithelial iNOS
Am. J. Respir. Crit. Care Med.,
December 1, 1999;
160(6):
2093 - 2099.
[Abstract]
[Full Text]
|
 |
|
Copyright © 1998 by the European Respiratory Society.
|