ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Farre, R
Right arrow Articles by Navajas, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Farre, R
Right arrow Articles by Navajas, D
Eur Respir J 1998; 11: 179-182
Copyright © ERS Journals Ltd 1998


Original Articles

Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopnoeas

R Farre, JM Montserrat, M Rotger, E Ballester, and D Navajas

The aim of this work was to assess the accuracy of thermistors/thermocouples as devices for detecting hypopnoeas in sleep studies. Conventional thermistor/thermocouples were studied with a respiratory model allowing the simulation of inspiratory (22 degrees C) and expiratory (37 degrees C) flows. The thermistor signal (V'th) was compared with a pneumotachograph (V'th): 1) for sinusoidal and square-wave airflows (+/-0.05 to +/-0.8 L.s(-1), 10-20 breaths.min(-1) (bpm)); 2) when changing the distance from the thermistor to the nose (0-20 mm); and 3) when doubling the section of the nostrils. The thermistor was strongly nonlinear and flow reductions (hypopnoeas) were underestimated: a 50% reduction in V' (+/-0.5 L.s(-1), 15 bpm, sinusoidal) resulted in only an 18% reduction in V'th. V'th depended considerably on the airflow pattern: for V'=+/-0.5 L.s(-1), V'th increased by 100% from sinusoidal (20 bpm) to square-wave (10 bpm). For V'=+/-0.5 L.s(-1), 15 bpm, sinusoidal flow, V'th increased by 79% when the distance thermistor-nose varied from 20-0 mm, and V'th decreased by 37% when doubling the nose section. We concluded that thermistor/thermocouples are inaccurate flow-measuring devices when used at the airflow conditions typical of sleep studies. Their use for quantifying hypopnoeas may lead to considerable underdetection of these respiratory events.


This article has been cited by other articles:


Home page
ChestHome page
B. V. Vaughn and P. Giallanza
Technical Review of Polysomnography
Chest, December 1, 2008; 134(6): 1310 - 1319.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
H. Nakano, T. Tanigawa, Y. Ohnishi, H. Uemori, K. Senzaki, T. Furukawa, and S. Nishima
Validation of a single-channel airflow monitor for screening of sleep-disordered breathing
Eur. Respir. J., October 1, 2008; 32(4): 1060 - 1067.
[Abstract] [Full Text] [PDF]


Home page
Proc Am Thorac SocHome page
H. Muzumdar and R. Arens
Diagnostic Issues in Pediatric Obstructive Sleep Apnea
Proceedings of the ATS, February 15, 2008; 5(2): 263 - 273.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
I. Koutsourelakis, G. Georgoulopoulos, E. Perraki, E. Vagiakis, C. Roussos, and S. G. Zakynthinos
Randomised trial of nasal surgery for fixed nasal obstruction in obstructive sleep apnoea
Eur. Respir. J., January 1, 2008; 31(1): 110 - 117.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
H. Nakano, T. Tanigawa, T. Furukawa, and S. Nishima
Automatic detection of sleep-disordered breathing from a single-channel airflow record
Eur. Respir. J., April 1, 2007; 29(4): 728 - 736.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
I. Koutsourelakis, E. Vagiakis, C. Roussos, and S. Zakynthinos
Obstructive sleep apnoea and oral breathing in patients free of nasal obstruction
Eur. Respir. J., December 1, 2006; 28(6): 1222 - 1228.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
R. B. Berry, G. L. Koch, S. Trautz, and M. H. Wagner
Comparison of Respiratory Event Detection by a Polyvinylidene Fluoride Film Airflow Sensor and a Pneumotachograph in Sleep Apnea Patients
Chest, September 1, 2005; 128(3): 1331 - 1338.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
C. Sahlin, E. Svanborg, H. Stenlund, and K. A. Franklin
Cheyne-Stokes respiration and supine dependency
Eur. Respir. J., May 1, 2005; 25(5): 829 - 833.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
R. Farre, J.M. Montserrat, and D. Navajas
Noninvasive monitoring of respiratory mechanics during sleep
Eur. Respir. J., December 1, 2004; 24(6): 1052 - 1060.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
A. Bachour and P. Maasilta
Mouth Breathing Compromises Adherence to Nasal Continuous Positive Airway Pressure Therapy
Chest, October 1, 2004; 126(4): 1248 - 1254.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
M.R. Madronio, E. Di Somma, R. Stavrinou, J.P. Kirkness, E. Goldfinch, J.R. Wheatley, and T.C. Amis
Older individuals have increased oro-nasal breathing during sleep
Eur. Respir. J., July 1, 2004; 24(1): 71 - 77.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
J R Stradling and R J O Davies
Sleep {middle dot} 1: Obstructive sleep apnoea/hypopnoea syndrome: definitions, epidemiology, and natural history
Thorax, January 1, 2004; 59(1): 73 - 78.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
P. Bottini, M.L. Dottorini, M. Cristina Cordoni, G. Casucci, and C. Tantucci
Sleep-disordered breathing in nonobese diabetic subjects with autonomic neuropathy
Eur. Respir. J., October 1, 2003; 22(4): 654 - 660.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
J.F. Masa, J. Corral, M.J. Martin, J.A. Riesco, A. Sojo, M. Hernandez, and N.J. Douglas
Assessment of thoracoabdominal bands to detect respiratory effort-related arousal
Eur. Respir. J., October 1, 2003; 22(4): 661 - 667.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
S. J. Heitman, R. S. Atkar, E. A. Hajduk, R. A. Wanner, and W. W. Flemons
Validation of Nasal Pressure for the Identification of Apneas/Hypopneas during Sleep
Am. J. Respir. Crit. Care Med., August 1, 2002; 166(3): 386 - 391.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
C. CRACOWSKI, J.-L. PEPIN, B. WUYAM, and P. LEVY
Characterization of Obstructive Nonapneic Respiratory Events in Moderate Sleep Apnea Syndrome
Am. J. Respir. Crit. Care Med., September 15, 2001; 164(6): 944 - 948.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
L. Hernandez, E. Ballester, R. Farre, J. R. Badia, R. Lobelo, D. Navajas, and J. M. Montserrat
Performance of Nasal Prongs in Sleep Studies : Spectrum of Flow-Related Events
Chest, February 1, 2001; 119(2): 442 - 450.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. FARRÉ, J. RIGAU, J. M. MONTSERRAT, E. BALLESTER, and D. NAVAJAS
Relevance of Linearizing Nasal Prongs for Assessing Hypopneas and Flow Limitation During Sleep
Am. J. Respir. Crit. Care Med., February 1, 2001; 163(2): 494 - 497.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
D. E. WEESE-MAYER, M. J. CORWIN, M. R. PEUCKER, J. M. DI FIORE, D. R. HUFFORD, L. R. TINSLEY, M. R. NEUMAN, R. J. MARTIN, L. J. BROOKS, S. L. DAVIDSON WARD, et al.
Comparison of Apnea Identified by Respiratory Inductance Plethysmography with That Detected by End-tidal CO2 or Thermistor
Am. J. Respir. Crit. Care Med., August 1, 2000; 162(2): 471 - 480.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J. ARGOD, J.-L. PÉPIN, R. P. SMITH, and P. LÉVY
Comparison of Esophageal Pressure with Pulse Transit Time as a Measure of Respiratory Effort for Scoring Obstructive Nonapneic Respiratory Events
Am. J. Respir. Crit. Care Med., July 1, 2000; 162(1): 87 - 93.
[Abstract] [Full Text]


Home page
Arch Fam MedHome page
E. C. Fletcher, J. Stich, and K. L. Yang
Unattended Home Diagnosis and Treatment of Obstructive Sleep Apnea Without Polysomnography
Arch Fam Med, February 1, 2000; 9(2): 168 - 174.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the European Respiratory Society.