Original Articles |
Measurement of nitric oxide levels in exhaled air is commonly performed using a chemiluminescence detector. However, water vapour and carbon dioxide affect the chemiluminescence process. The influence of these gases at the concentrations present in exhaled air, has not yet been studied. For this in vitro study, mixtures of 50, 100 and 200 parts per billion (ppb) NO in air were prepared and fed into the NO analyser either directly or bubbled through water. Mixtures with CO2 were prepared by adding 0-10% CO2 to the diluent air. We found a significant decrease in NO readings in the water-saturated samples compared to the dry gas (p < 0.001), strongly dependent on the partial pressure of water. NO levels in exhaled air (mean 10 +/- 2 ppb) showed a decrease of 17 +/- 3% when water vapour was not absorbed. From the experiments with CO2 we found a decrease in NO reading of 1.04 +/- 0.07% per volume CO2 (%). Presence of water vapour, thus, leads to a systematic underestimation of NO levels. Insertion of a water absorber might, therefore, be advantageous. The influence of CO2 concentrations in the normal respiratory range is negligible. With high expiratory CO2 levels as applied in permissive hypercapnia, the effects may be substantial.
This article has been cited by other articles:
![]() |
ATS/ERS Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide, 2005 Am. J. Respir. Crit. Care Med., April 15, 2005; 171(8): 912 - 930. [Full Text] [PDF] |
||||
![]() |
G L Piacentini, A Bodini, D G Peroni, M M. Del Giudice Jr, S Costella, and A L Boner Reduction in exhaled nitric oxide immediately after methacholine challenge in asthmatic children Thorax, September 1, 2002; 57(9): 771 - 773. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. de JONGSTE and K. ALVING Gas Analysis Am. J. Respir. Crit. Care Med., August 1, 2000; 162(2): S23 - 27. [Full Text] [PDF] |
||||
![]() |
P. Silkoff Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide in Adults and Children---1999 . THIS OFFICIAL STATEMENT OF THE AMERICAN THORACIC SOCIETY WAS ADOPTED BY THE ATS BOARD OF DIRECTORS, JULY 1999 Am. J. Respir. Crit. Care Med., December 1, 1999; 160(6): 2104 - 2117. [Full Text] |
||||
![]() |
P. Murtz, L. Menzel, W. Bloch, A. Hess, O. Michel, and W. Urban LMR spectroscopy: a new sensitive method for on-line recording of nitric oxide in breath J Appl Physiol, March 1, 1999; 86(3): 1075 - 1080. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |