ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Devadason, S.
Right arrow Articles by Le Souef, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Devadason, S.
Right arrow Articles by Le Souef, P.
Eur Respir J 1997; 10: 2023-2028
Copyright © ERS Journals Ltd 1997


Original Articles

Lung deposition from the Turbuhaler in children with cystic fibrosis

SG Devadason, ML Everard, C MacEarlan, C Roller, QA Summers, P Swift, L Borgstrom, and PN Le Souef

Drug delivery to patients using dry powder inhalers, such as the Turbuhaler, is believed to be influenced by the inspiratory flow used. Clinical studies have indicated that this delivery system can be used effectively by children. However, it is not known how the total and weight-corrected dose delivered to the airways varies with age. A deposition study using technetium-99m (99mTc)-labelled budesonide was performed in order to determine the effect of age on delivery. Twenty one children with cystic fibrosis, aged 4-16 yrs, were recruited. They were clinically stable with normal lung function. Initially, a gamma camera scan was taken in front of a flood source containing 37 MBq of 99mTc. Subsequently, subjects inhaled through a low resistance inspiratory filter connected to a commercially available Turbuhaler. Immediately afterwards they inhaled from a noncommercial Turbuhaler containing budesonide labelled with 99mTc, and then underwent anterior and posterior gamma camera scans. Both Turbuhaler inhalers were attached to a portable spirometer and the peak inspiratory flow through the Turbuhaler was recorded for each inhalation. The total body dose was calculated from the dose deposited on the inspiratory filter connected to the commercial Turbuhaler. Analysis of the gamma camera images provided information on the proportion of the radiolabel delivered to the lungs compared to that deposited in the upper airway and stomach. As expected, a highly significant positive correlation was noted between the peak inspiratory flow generated by the patient through the Turbuhaler and the dose delivered to the lung. Similarly, there was a highly significant positive correlation between age and "total lung dose". However, when total lung dose was corrected for body weight, there was a nonsignificant negative correlation with age. This study suggests that the "weight-corrected lung dose" achieved when children aged > 6 yrs use the Turbuhaler, is largely independent of age. It would appear that the flow-dependent properties of this device are such that the reduced peak inspiratory flow generated by younger children results in a lower dose to the lungs, but that this is off-set by their lower body weight. This is unlikely to be a property of other devices with different flow/drug delivery characteristics.


This article has been cited by other articles:


Home page
Eur Respir JHome page
R. Petersen, L. Agertoft, and S. Pedersen
Treatment of exercise-induced asthma with beclomethasone dipropionate in children with asthma
Eur. Respir. J., December 1, 2004; 24(6): 932 - 937.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
L. Agertoft and S. Pedersen
Lung Deposition and Systemic Availability of Fluticasone Diskus and Budesonide Turbuhaler in Children
Am. J. Respir. Crit. Care Med., October 1, 2003; 168(7): 779 - 782.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
S.G. Devadason, T. Huang, S. Walker, R. Troedson, and P.N. Le Souef
Distribution of technetium-99m-labelled QVARTM delivered using an AutohalerTM device in children
Eur. Respir. J., June 1, 2003; 21(6): 1007 - 1011.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child.Home page
L Agertoft, A Andersen, E Weibull, and S Pedersen
Systemic availability and pharmacokinetics of nebulised budesonide in preschool children
Arch. Dis. Child., March 1, 1999; 80(3): 241 - 247.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the European Respiratory Society.