Original Articles |
The aim of this study was to determine whether the nitric oxide (NO) measured in exhaled air is produced at airway or alveolar level. Exhaled NO was measured using a chemiluminescence analyser, and carbon dioxide (CO2 concentration using a Morgan capnograph in single exhalations in 12 healthy subjects (mean age 32 yrs; 6 males and 6 females). For each subject, five exhalations were made directly into the NO analyser and five were made through a T-piece system, which allowed measurement of expiratory flow rate. The peak NO levels measured via the T-piece system were 41.2 (SEM 10.8) parts per billion (ppb), significantly lower than direct levels 84.8 (14.0) ppb (p<0.001). The levels of NO tended to rise to an early peak and plateau, while the CO2 levels continued to rise to peak late in the exhalation. The mean times to reach peak NO levels were 32.2 s (direct) and 23.1 s (T-piece), which were significantly different from that of peak CO2 levels 50.5 s (direct) and 51.4 s (T-piece) (p<0.001). At peak NO level, the simultaneous CO2 level mean 4.9% (SEM 0.14)%, was significantly lower than the peak CO2 reached, 5.8 (0.21)% (p<0.001). We conclude that peak nitric oxide levels are dependent on measurement conditions. There are significant differences between the time to peak of carbon dioxide and nitric oxide. Therefore, most nitric oxide, unlike carbon dioxide, is produced in airways and not at alveolar level.
This article has been cited by other articles:
![]() |
ATS/ERS Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide, 2005 Am. J. Respir. Crit. Care Med., April 15, 2005; 171(8): 912 - 930. [Full Text] [PDF] |
||||
![]() |
D. J. Vaughan, T. V. Brogan, M. E. Kerr, S. Deem, D. L. Luchtel, and E. R. Swenson Contributions of nitric oxide synthase isozymes to exhaled nitric oxide and hypoxic pulmonary vasoconstriction in rabbit lungs Am J Physiol Lung Cell Mol Physiol, May 1, 2003; 284(5): L834 - L843. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Shinkai, S. Suzuki, A. Miyashita, H. Kobayashi, T. Okubo, and Y. Ishigatsubo Analysis of Exhaled Nitric Oxide by the Helium Bolus Method* Chest, June 1, 2002; 121(6): 1847 - 1852. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. DELCLAUX, B. MAHUT, F. ZERAH-LANCNER, C. DELACOURT, S. LAOUD, D. CHERQUI, C. DUVOUX, A. MALLAT, and A. HARF Increased Nitric Oxide Output from Alveolar Origin during Liver Cirrhosis versus Bronchial Source during Asthma Am. J. Respir. Crit. Care Med., February 1, 2002; 165(3): 332 - 337. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. R. Thomas, S. A. Kharitonov, S. F. Scott, M. E. Hodson, and P. J. Barnes Nasal and Exhaled Nitric Oxide Is Reduced in Adult Patients With Cystic Fibrosis and Does Not Correlate With Cystic Fibrosis Genotype Chest, April 1, 2000; 117(4): 1085 - 1089. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Silkoff Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal Nitric Oxide in Adults and Children---1999 . THIS OFFICIAL STATEMENT OF THE AMERICAN THORACIC SOCIETY WAS ADOPTED BY THE ATS BOARD OF DIRECTORS, JULY 1999 Am. J. Respir. Crit. Care Med., December 1, 1999; 160(6): 2104 - 2117. [Full Text] |
||||
![]() |
P. Murtz, L. Menzel, W. Bloch, A. Hess, O. Michel, and W. Urban LMR spectroscopy: a new sensitive method for on-line recording of nitric oxide in breath J Appl Physiol, March 1, 1999; 86(3): 1075 - 1080. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Corradi, A. Pelizzoni, M. Majori, A. Cuomo, E. d. Munari, and A. Pesci Influence of atmospheric nitric oxide concentration on the measurement of nitric oxide in exhaled air Thorax, August 1, 1998; 53(8): 673 - 676. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |