Eur Respir J 1997; 10: 910-913
Copyright © ERS Journals Ltd 1997


Clinical Trial

Effects of four different methods of sampling arterial blood and storage time on gas tensions and shunt calculation in the 100% oxygen test

FW Smeenk, JD Janssen, BJ Arends, GA Harff, JA van den Bosch, JP Schonberger, and PE Postmus

At the present time, plastic syringes are most commonly used for collecting arterial blood. The oxygen tension of the arterial blood (Pa,O2) in these syringes may fall. We studied the effect of the type of syringe, metabolism, and storage time on the arterial oxygen pressures measured and on the pulmonary shunt calculated. In 10 patients, 2-3 h after aortacoronary bypass surgery, a 100% oxygen test was performed. Four arterial blood gas samples were withdrawn from each patient in random order, two in glass syringes and two in plastic syringes. One glass and one plastic syringe were stored at room temperature (RT), and the others were stored in ice-water (IW). Each sample was analysed as soon as possible, and repeated 15, 30, 60 and 120 min after sampling. The Pa,O2 measurement in blood in the glass syringe in IW measured as soon as possible after sampling was considered the "gold standard". Pulmonary shunt calculations were performed using the results of the various blood gas analyses. Compared with the "gold standard", all of the other methods showed significant deterioration in the Pa,O2 measurement. The effect due to diffusion was 0.05 kPa x min(-1), and that due to metabolism 0.11 kPa x min(-1). The Pa,O2 in the glass syringes stored in IW remained stable with time. The pulmonary shunt was significantly overestimated when the "gold standard" blood gas results were not used (range 0.8-9.9%). Glass (not plastic) syringes should be used in the 100% oxygen test. The syringe should be cooled immediately, even when the sample is analysed as soon as possible.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
P. B. Batchelder and D. M. Raley
Maximizing the Laboratory Setting for Testing Devices and Understanding Statistical Output in Pulse Oximetry
Anesth. Analg., December 1, 2007; 105(6S_Suppl): S85 - S94.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. P. d'Ortho, C. Delclaux, F. Zerah, R. Herigault, S. Adnot, and A. Harf
Use of Glass Capillaries Avoids the Time Changes in High Blood PO2 Observed With Plastic Syringes
Chest, November 1, 2001; 120(5): 1651 - 1654.
[Abstract] [Full Text] [PDF]